Call Us: 954-371-1370 Email: info@powerfenceinc.com 902 SW 2nd Place, Pompano Beach, FL 33069
Licensed & Insured - Broward Lic. 20-F-21831-X
Palm Beach Lic. U-22529
Reviewed Apr 2026 Read 16 min Sections 8
A Homeowner's Handbook - City of Weston

In Weston, it goes on paper first.

Weston is a master-planned city of lakes, landscape easements and homeowners' associations, and most fence projects here turn on paperwork before posts. The two most popular choices - a PVC privacy fence or a black aluminum fence - need signed-and-sealed engineered plans. Stay 25 ft off the lake and landscape maintenance easements, set any fence along a street 3 ft back behind a continuous hedge, clear Planning & Zoning review before the building permit, and remember your HOA can be stricter than the City.

6 ftSide & rear height
25 ftOff lake & landscape easements
Sealed plansFor PVC & metal fences
3 ft + hedgeAlong a right-of-way
01
Start here - heights, the open front & the street hedge

Six feet, an open front, a hedge at the street.

Weston's heights are conventional and easy to remember. The two things that surprise people are at the front of the house and along any street frontage - that's where Weston adds rules most cities don't.

How tall

  • Up to 6 ft on residentially zoned property - the standard side and rear height.
  • Up to 8 ft where a residential fence or wall abuts nonresidentially zoned property (for example, backing a commercial parcel).

Keep the front open

A fence or wall may not be erected in front of the principal structure, and on the side it may not extend beyond the front of the house on the side where it sits. In plain terms, your fence starts at the front wall of the house and runs toward the back - the front yard stays open.

On your land, off the lines

Weston's code doesn't set a numeric setback from your side or rear property lines for a standard residential fence - but the fence must be entirely on your own property, and:

  • It may not encroach into rights-of-way or easements, or onto adjacent properties.
  • It may not impede or impair drainage to or from the property next door.
  • It may not connect to a neighbor's fence - every fence must stand on its own posts.

The street-frontage rule: 3 ft back, behind a hedge

This is the distinctive one. Where a fence or wall abuts a right-of-way, it must be set back at least 3 feet from the right-of-way line, and a continuous hedge must be planted in that gap, between the right-of-way and the fence. The hedge has to be at least 4 ft tall at planting, kept at a minimum of 4 ft, and may not grow taller than the fence. So a street-side fence is really a fence plus a maintained green screen - plan and budget for both.

FIG. 01 - WHERE A FENCE CAN GO - PLAN VIEW PRIMARY STREET (PRINCIPAL FRONTAGE) SIDEWALK / ROW SIDE STREET - ROW NONRESIDENTIAL ZONING BEHIND ? rear may be 8 FT HOUSE FRONT LINE OF HOUSE - no fence forward of this FRONT YARD - NO FENCE REAR = 6 FT (8 FT if abutting nonresidential) SIDE = 6 FT 3 FT CONTINUOUS HEDGE FENCE = 6 FT
Fig. 01 - Open front, hedge at the street
The fence starts at the front wall of the house
  • No fence in front of the principal structure.
  • Side & rear up to 6 ft.
  • Rear up to 8 ft only where it abuts nonresidential zoning.
  • At a ROW: 3-ft setback + a continuous hedge in front.
FIG. 01b - THE STREET-SIDE HEDGE - CROSS-SECTION grade STREET / ROW ? public side CONTINUOUS HEDGE - = 4 FT, = fence height FENCE = 6 FT = 3 FT SETBACK YOUR YARD
Fig. 01b - A fence plus a green screen
Hedge between the fence and the street
  • Continuous hedge, = 4 ft at planting and maintained.
  • Fence set back = 3 ft from the ROW line.
  • The hedge may not grow taller than the fence.
  • Applies to any frontage where a fence abuts a ROW.
6 ftResidential

Standard side and rear height on residentially zoned property.

8 ftAbuts nonresidential

Allowed where the residential fence abuts nonresidentially zoned property.

3 ftSetback at a ROW

Plus a continuous hedge (= 4 ft) planted between the fence and the street.

The Weston shape

Picture a fence that starts at the front wall of your house and runs back at 6 ft, on its own posts and clear of every line. Along any street it sits 3 ft back behind a maintained hedge, and it reaches 8 ft only where it backs nonresidential zoning. Next come the two things that really shape a Weston project: the lake & landscape easements (section 2) and the engineered-plan rule for PVC and metal (section 3).

02
The single biggest issue in this city

Stay 25 feet off the lakes and landscape easements.

Weston was platted around an interconnected system of lakes, canals and landscaped buffer tracts, and the easements that protect them cross a large share of its lots. More fence projects get reshaped - or stopped - by an easement here than by any height rule. If your lot touches a lake, a canal or a landscaped common area, this is the section to get right first.

The two 25-foot setbacks

Weston's fence zoning requirements call for a 25-ft minimum setback from the Lake Maintenance Easement and a 25-ft minimum setback from the Landscape Maintenance Easement. Where those apply, the back or side of your lot effectively has a wide no-fence band - so locate the fence inside the 25 ft, not at the water's edge or the tract line.

No fence in these easements at all

Beyond the setbacks, the Code is firm: no fence or wall may encroach into any drainage, water and sewer, lake access, or lake maintenance easement, and fences may not encroach into a landscape maintenance easement. These strips exist so the City and the utilities can reach and maintain the water and landscape systems - a fence in the way can be required to come out, at your expense.

Drainage, neighbors & your own posts

  • A fence may not impede or impair drainage to or from adjacent property - important where lots grade toward a lake or swale.
  • Fences may not encroach onto adjacent properties and may not connect to a neighbor's fence; each fence stands on its own individual posts.

Before you dig - and one narrow exception

Florida law requires Sunshine 811 notice at least 2 full business days before any excavation, including fence post holes. And there's one narrow relief valve: for a fence installed before 2005 inside a lake maintenance easement, the Code allows an administrative variance to replace it in the exact location with an encroachment of up to 10% of the easement width, subject to the conditions in - 124.80(F)(2)(b). That's for replacing an old fence in place - not for building a new one in the easement.

FIG. 02 - LAKE & LANDSCAPE EASEMENTS - KEEP CLEAR LAKE LAKE MAINTENANCE EASEMENT - NO FENCE LANDSCAPE MAINT. EASEMENT - NO FENCE DRAINAGE / UTILITY EASEMENT - NO FENCE 25 FT SETBACK FROM THE EASEMENT FENCE - inside the 25 ft, off every easement HOUSE No fence in drainage, water/sewer, lake access, lake maintenance or landscape easements - Sunshine 811 = 2 business days before digging.
Fig. 02 - The water and the buffers get right of way
Inside the 25 ft, off every easement
  • 25-ft setback from the Lake Maintenance Easement.
  • 25-ft setback from the Landscape Maintenance Easement.
  • No fence in drainage, water/sewer or lake easements.
  • Own posts; don't impede drainage or cross the line.
Confirm the easement first

If your lot touches a lake, canal or landscaped tract, read your survey and confirm the easement lines before you design the fence. Weston wants a 25-ft setback from the lake and landscape maintenance easements and no fence at all in drainage, water/sewer, lake-access or maintenance easements - a fence in the wrong place can be pulled at your cost.

03
The Weston permit surprise

PVC and metal fences need an engineer.

This is the rule that catches almost everyone in Weston - because the two most popular fences in the city are exactly the ones it applies to. If you're picturing a white PVC privacy fence or a black aluminum/ornamental fence, read this before you get attached to a quote.

PVC or metal ? signed and sealed plans

Weston's quick-permit fence checklist states that signed and sealed plans by a Florida licensed architect or engineer are required when installing a PVC or metal fence. There's no prescribed shortcut for those materials - the engineering is part of the project, so build the cost and the lead time into your plan from day one.

Wood and chain link ? the prescribed method

By contrast, wood and chain-link fences may be installed under the prescribed method of the Florida Building Code if they're not designed by an architect or engineer. A standard wood privacy fence or a vinyl-coated chain-link fence usually doesn't need sealed plans - which is why those two materials are the simplest path through Weston permitting.

Everything else ? design to the FBC (8th Edition, 2023)

Aluminum, PVC, chain link with restricted airflow, and any other fence type not covered by the City's listed construction method must be designed to meet the Florida Building Code, 8th Edition (2023). In practice that loops back to the same place: an engineer's design, or an approved product.

Pre-manufactured sections & product approval

Buying pre-made panels doesn't get you out of it. Pre-manufactured fence sections may not comply with the applicable code, so a product approval (Notice of Acceptance) may be required. Any construction method not specified in Weston's installation handout must follow plans prepared by an architect or engineer, or an authorized product-approval NOA.

FIG. 03 - WHICH MATERIAL NEEDS AN ENGINEER? PICK A MATERIAL PVC - METAL - ALUMINUM incl. restricted-airflow chain link ? SIGNED & SEALED PLANS by a FL licensed architect / engineer or design to FBC 8th Ed. (2023) WOOD - CHAIN LINK standard styles, not engineer-designed ? PRESCRIBED FBC METHOD no sealed plans needed - the simplest path Pre-manufactured sections? A product approval (NOA) may be required either way.
Fig. 03 - Two paths through Weston permitting
The material you pick decides the paperwork
  • PVC & metal: signed & sealed engineered plans.
  • Wood & chain link: prescribed FBC method, no seal.
  • Pre-made panels: product approval (NOA) may apply.
  • Anything uncovered: design to FBC 8th Ed. (2023).
Choosing your material

If you want the simplest, fastest permit, a wood or vinyl-coated chain-link fence can ride the prescribed FBC method with no sealed plans. Set your heart on white PVC or black aluminum and you'll need engineered, signed-and-sealed plans - worth it for the look, but budget the engineering and lead time up front.

04
Where the driveway and corners meet the street

Keep the corner clear - and the 2-to-8-ft band open.

Weston protects driver and pedestrian sightlines under - 125.56, with a few differently-sized triangles plus a clear band that matters as much as the triangle itself. Which one applies depends on what's meeting the travel way.

Private driveway meets a public street: 10 - 50

Where your private driveway intersects a public right-of-way, no sight obstruction is allowed within a 10-ft by 50-ft triangular area. The long 50-ft leg runs along the street; the 10-ft leg runs up your driveway.

Slow local street: reduce to 10 - 35

That driveway triangle may be reduced to 10 ft by 35 ft, subject to City approval, if the public roadway is a local street posted at 25 mph or less. On a quiet residential street, that gives you a little more room.

On-site intersections: 10 - 25

For on-site intersections of private internal roadways, driveways or drive aisles, keep a 10-ft by 25-ft triangle clear, measured from the intersecting edges of the travel way.

The part people miss: the 24-to-96-inch band

Inside any intersection triangle you must keep cross-visibility clear between 24 inches and 96 inches (2 ft to 8 ft) above the center of the adjacent intersection. No signs, hedges, shrubbery, trees or other obstructions in that window. Anything below 2 ft (low planting, a low wall) or above 8 ft (a high tree canopy) is fine - it's the 2-to-8-ft band that has to stay see-through.

The 100-foot rule & crosswalks

Any fence, hedge or object that would obstruct sight within 100 feet of a driveway or cross street must be kept outside the clear sight triangle. Sight areas are also protected where a crosswalk meets a driveway, access aisle or right-of-way (- 125.56(D)).

FIG. 04 - SIGHT TRIANGLES (-125.56) + THE 2-8 FT BAND DRIVEWAY - STREET PUBLIC STREET DRIVEWAY 50 FT 10 - 50 ? 10 - 35 if = 25 mph 10 FT HOUSE ON-SITE - 10 - 25 drive aisle 25 FT ? 10 FT internal roadways, driveways, aisles CLEAR BAND grade 24 - 96 IN keep see-through < 24 in OK (low) > 96 in OK (canopy) 2' 8'
Fig. 04 - Different triangles, one clear band
Size depends on what meets the travel way
  • Driveway - public street: 10 - 50 ft.
  • Reduce to 10 - 35 on a = 25 mph local street.
  • On-site intersections: 10 - 25 ft.
  • Keep 24-96 in (2-8 ft) above grade see-through.
Corner & driveway homeowners

Use the right triangle - 10 - 50 where your driveway meets a public street (10 - 35 on a slow local street), 10 - 25 at on-site intersections - and keep the 2-to-8-ft band see-through inside it. A low wall under 2 ft or open ornamental metal through the corner both clear it cleanly.

05
What you can build with

Vinyl-coated chain link, finished-side-out wood.

Weston's material rules are less about a fixed allowed list and more about finish, safety and good neighborliness - with a handful of firm prohibitions and some specific chain-link and wood requirements.

Prohibited outright

Barbed wire, electrified fencing, barbed-wire-topped fencing and razor-wire-topped fencing are prohibited. None of those belong on a Weston residential lot.

Chain link - three specifics

If you go with chain link, it must meet all three: black or green vinyl coating (no bare galvanized look), knuckled at the top and bottom, and fitted with both a top and a bottom rail.

Wood - built to last, finished side out

Wood fences must be decay- and termite-resistant material, designed to the applicable Florida Building Code load requirements, and installed with corrosion-resistant fasteners. The recognizable finished side must face adjacent properties and rights-of-way - your neighbors and the street see the good side.

Aluminum, PVC & the rest

Materials not covered by the City's listed construction method must be designed to the Florida Building Code, 8th Edition (2023) - and remember from section 3 that PVC and metal need signed-and-sealed plans, with a product approval (NOA) where pre-manufactured sections are used.

Build with these

Permitted

  • Wood - decay/termite-resistant, corrosion-resistant fasteners, finished side out.
  • Vinyl-coated chain link (black or green) - knuckled top & bottom, both rails.
  • Aluminum & ornamental metal - engineered/sealed plans.
  • PVC - engineered/sealed plans.
  • Masonry & other types designed to the FBC 8th Ed. (2023).
Leave these out

Prohibited

  • Barbed wire & barbed-wire-topped fencing.
  • Razor-wire-topped fencing.
  • Electrified fencing.
  • Bare (uncoated) chain link.
  • Wood with the finished side turned inward.
FIG. 05 - CHAIN-LINK - WHAT WESTON REQUIRES grade TOP RAIL (required) BOTTOM RAIL (required) VINYL-COATED MESH black or green REQUIRED Knuckled top Knuckled bottom Top rail Bottom rail Black/green vinyl Bare galvanized = not allowed
Fig. 05 - The Weston chain-link spec
Coated, knuckled, and railed top & bottom
  • Black or green vinyl coating.
  • Knuckled selvage at top and bottom.
  • Both a top rail and a bottom rail.
  • Standard chain link rides the prescribed FBC method.
Finish matters in Weston

Two finish rules trip people up: chain link must be vinyl-coated, knuckled top and bottom, with both rails (no bare galvanized), and wood must show its finished side out toward neighbors and the street. And remember - a PVC or metal fence still needs engineered, sealed plans.

06
The rulebook on top of the City's

Your HOA can be stricter than the City.

Weston is built almost entirely of master-planned villages and homeowners' associations, so for most homes there are two rulebooks, not one: the City code in this handbook, and your community's recorded private restrictions. A fence has to satisfy both.

They operate independently

Private covenants, HOA rules, architectural control board (ARB) requirements and recorded neighborhood restrictions operate independently from City fence rules. A fence that fully meets City of Weston requirements may still be limited or prohibited by your private restrictions - the City won't check your covenants for you.

What they often control

Private restrictions frequently regulate fence type, color, material, height, placement, finished-side orientation and approval procedures - often more strictly than the Code. Many Weston villages specify a particular style or limit fencing to certain materials or colors, which is why two homes a mile apart can have very different "allowed" fences.

Do this first

Get your HOA / ARB approval in writing before you order materials or file the permit. An association can require you to remove a non-conforming fence even after the City approves it, so the safe sequence is: HOA sign-off, then design to the stricter of the two rulebooks, then permit.

FIG. 06 - TWO RULEBOOKS - THE STRICTER ONE WINS CITY OF WESTON CODE heights - placement - easements sight triangles - materials - permit e.g. up to 6 ft, vinyl-coated chain link allowed + HOA / ARB RESTRICTIONS type - color - material - height placement - finished side - approval e.g. only black aluminum, no chain link in front YOUR FENCE MUST SATISFY BOTH ? THE STRICTER RULE CONTROLS
Fig. 06 - City code + your covenants
Design to whichever rule is tighter
  • City code sets the baseline minimums.
  • HOA / ARB rules often go further.
  • The fence must meet both - stricter wins.
  • Get HOA approval in writing first.
Get HOA sign-off first

A City-approved fence can still violate your HOA or ARB rules - and the association can make you tear it out. Before you order materials or file the permit, get your community's approval in writing, then design to the stricter of the two rulebooks.

07
What you file & in what order

Zoning review first, then the building permit.

Fence work is handled as a Quick Building Permit in Weston, but the order is the thing to get right: Planning & Zoning reviews and approves before you apply for the building permit. Skipping that step sends the application back.

Two-step approval

The Planning & Zoning / Development Services Department reviews the development criteria - setbacks, easements, right-of-way frontage, sight-distance areas and your site-plan information - and must approve before building permit application. Then Permitting / Building Code Services handles intake, the building-code plan review and inspection scheduling.

The submittal

  • A Broward County Uniform Building Permit Application (Weston's fence checklist calls for it).
  • Required plans or construction documents, and product approvals when required.
  • A survey, plus a site plan showing the proposed fence and its setback dimensions to the property lines - unless those dimensions already appear on the survey.
  • For PVC or metal, the signed-and-sealed plans from section 3.

Permit before work

Weston's quick-permit instructions require plan approval and permit issuance before work begins. Don't set a post until the permit is in hand.

HB 803 - the new $7,500 exemption

Effective July 1, 2026, Florida's HB 803 requires permit-issuing cities to exempt a single-family owner (or their contractor) from the building permit for work valued under $7,500, on a written exemption request with documentation of value. The limits: it doesn't apply in a flood-hazard area, or to electrical, plumbing, structural, mechanical or gas work, and it waives only the building-permit step - it does not remove Weston's zoning, fence, setback, easement, right-of-way, sight-visibility, HOA or other approvals. Because the law is new, ask the receiving department how to file the request and confirm what still applies before relying on it.

Fig. 07 - A Weston fence permit - review first, then build
Start Survey + design Set heights, material, easement setbacks & sight triangles; get HOA sign-off.
Step 01 Planning & Zoning review Setbacks, easements, ROW & sight distance approved before you apply.
Step 02 Building permit Broward application + survey/site plan; sealed plans or NOA for PVC/metal.
Step 03 Permit & build Build to plan; call Sunshine 811 = 2 business days before digging.
Done Inspection Building review/inspection confirms heights, finish & placement.
Order matters - and HB 803 doesn't waive the rest

Get Planning & Zoning approval before you file the building permit, and don't build before issuance. And note: the $7,500 HB 803 exemption only touches the building-permit step - it doesn't waive Weston's zoning, easement, setback, sight-triangle or HOA requirements, and it doesn't apply in flood-hazard areas.

08
Quick reference & FAQ

The whole handbook, on one page.

City of Weston residential fence - at a glance

Source: City of Weston Code of Ordinances; Land Development Code - 124.33 (Fences & Walls) & - 125.56 (Sight Distance); City fence zoning requirements; Quick Building Permit materials; wood installation requirements & Code Enforcement guidance - reviewed Apr 2026 - confirm specifics with the City
Residential height
Up to 6 ft on residentially zoned property.
Abutting nonresidential
Up to 8 ft where a residential fence abuts nonresidential zoning.
Front yard
No fence in front of the principal structure, or extending beyond its front on that side.
Property lines
No numeric setback stated, but the fence must sit entirely on your property and out of ROWs/easements.
Abutting a right-of-way
Set back = 3 ft + a continuous hedge (= 4 ft, = fence height) between fence and street.
Lake maintenance easement
25-ft minimum setback; no fence inside the easement.
Landscape maintenance easement
25-ft minimum setback; no fence inside it.
Other easements
No fence in drainage, water/sewer or lake-access easements.
Drainage & neighbors
Can't impede drainage, encroach on neighbors, or connect to their fence - own posts.
PVC & metal fences
Require signed & sealed plans by a FL licensed architect/engineer.
Wood & chain link
May use the prescribed FBC method if not engineer-designed.
Other types
Design to the Florida Building Code, 8th Ed. (2023); product approval (NOA) for pre-made sections.
Sight triangle - driveway
10 - 50 ft; reducible to 10 - 35 on a = 25 mph local street (City approval).
Sight triangle - on-site
10 - 25 ft at internal roadway/driveway/aisle intersections.
Clear band
Keep 24-96 in (2-8 ft) above grade see-through; obstruction rule within 100 ft.
Chain link
Black or green vinyl coat, knuckled top & bottom, top + bottom rail.
Wood
Decay/termite-resistant, corrosion-resistant fasteners, finished side out.
Prohibited
Barbed wire, razor wire, electrified & barbed-/razor-wire-topped fencing.
HOA / private restrictions
Apply on top of City rules; can be stricter - get written ARB approval first.
Approval order
Planning & Zoning review & approval before the building permit application.
Permit submittal
Broward County application + plans/product approvals + survey + site plan with setback dimensions.
Permit timing
Approval & issuance required before work begins.
Sunshine 811
Notice = 2 full business days before any excavation, including post holes.
HB 803 exemption
Owner work under $7,500 by written request. Not in flood-hazard areas or for electrical/plumbing/structural/mechanical/gas; doesn't waive zoning, easement, visibility or HOA rules.
Reviewed as of
April 2026. Confirm current requirements with the City of Weston before ordering materials.

Good to know

Frequently asked questions

Can I put a fence in my front yard?

No. In Weston a fence or wall may not be erected in front of the principal structure, and on the side it can't extend beyond the front of the house. The fence starts at the front wall and runs back.

How tall can my fence be?

Up to 6 ft on residentially zoned property, and up to 8 ft where it abuts nonresidentially zoned property. Along any street frontage it also has to sit 3 ft back behind a continuous hedge.

Why does a white PVC or black aluminum fence cost more here?

Because Weston requires signed-and-sealed plans by a Florida licensed architect or engineer for PVC or metal fences. Wood and chain link can use the prescribed Florida Building Code method instead, which is why they're the simplest permits.

My lot backs a lake - what changes?

A lot. Weston wants a 25-ft setback from the Lake Maintenance Easement (and from the Landscape Maintenance Easement), and no fence at all in any drainage, water/sewer, lake-access or maintenance easement. Confirm the easement lines on your survey before you design.

What's the hedge rule along the street?

Where a fence abuts a right-of-way, it must be set back at least 3 ft and a continuous hedge planted between the fence and the street - at least 4 ft high, kept at 4 ft, and not taller than the fence.

What are the sight-triangle rules at my driveway or corner?

Where a driveway meets a public street it's a 10 - 50 ft triangle (reducible to 10 - 35 on a = 25 mph local street); on-site intersections use 10 - 25. Keep the view between 24 and 96 inches above grade see-through inside it.

What kind of chain link is allowed?

It must be black or green vinyl-coated, knuckled at the top and bottom, and have both a top and a bottom rail. Bare galvanized chain link isn't permitted.

Does my HOA still get a say?

Yes - and often the bigger say. Private covenants, HOA and ARB rules operate independently from the City and can be stricter on type, color, material, height and placement. A City-approved fence can still be required to come out by the HOA, so get written approval first.

In what order do the approvals happen?

Planning & Zoning reviews and approves first, then you apply for the building permit; work can't begin until the permit is issued. Plan for the two-step sequence.

Does HB 803's $7,500 exemption let me skip the permit?

It can exempt owner work under $7,500 from the building-permit step with a written request - but it doesn't apply in a flood-hazard area or to electrical/plumbing/structural/mechanical/gas, and it doesn't waive Weston's zoning, easement, setback, sight-triangle or HOA rules. Confirm with the City first.

Have a question we didn't cover?

Fencing a home
in Weston?

We know the Weston rulebook cold - the open front, 6-ft sides and rear, the 25-ft lake and landscape easement setbacks, the 3-ft right-of-way setback with its required hedge, the -125.56 sight triangles, and the big one: PVC and metal fences need signed-and-sealed engineered plans. We set the fence on your survey and off every easement, draw the site plan with setback dimensions, line up the engineering or product approval where it's needed, and run it through Planning & Zoning and the building permit - in the right order - so it clears before we set a post.

Call 954-371-1370 Licensed & insured - Broward Lic. 20-F-21831-X

Financing available

Fence now. Pay over time.

Power Fence can help customers explore monthly payment options through Wisetack for eligible fence, gate, and railing projects.

UP TO 25K ELIGIBLE PROJECTS Fast customer prequal No prepayment penalty

Ask about financing

Financing subject to credit approval. Payment options are provided by Wisetack lending partners.